SMT-203 Anesthesia Machine

  • Details

  • Parameters

  • Feature

    ■ integragted design, compact structure, fine and elegant
    ■ High quality, durable, friendly operation and simple maintenance
    ■ Rugged metal enclosure
    ■ Highlight ceiling lighting system
    ■ Retractable WordPad, save space
    ■ Lift arm mechanism, convenient and flexible operation
    ■ 5.7” high-luminance LCD display
    Feature

Specifications:

Main unit

■ Working modes: For the closed system, half closed system and half open system

■ Application: Adult and Child

■ Low gas supply alarm: when O2 supply pressure is over low, the machine will

arise > (longer than) 7 seconds audible alarm.

■ High pressure limitation: when airway pressure is higher than pre-set figure, the machine will automatically start protection function. The airway pressure will stop increasing (not increase any more) to keep patient safe.

■ Low pressure protection: when O2 gas supply pressure is lower than 0.1MPa,the machine will automatically cut off N2O supply.

■ When power supply fails, audible and visual alarms will arise.

■ O2 Flush: 25L/min~75L/min

■ Gas Supply: O2: 0.28MPa~0.6MPa  N2O: 0.28MPa~0.6MPa

■ Power supply: AC 220V, 50 Hz

 

Flow Meter

■ O2/N2O four-tube Flowmeter (0~1L/min 1~10L/min )

■ Linkage of O2 and N2O, keep oxygen concentration over 25%

 

Anesthesia Ventilator

■ Bellow for Adult 1 piece

■ Pneumatically driven and electrically control

■ Monitoring: Tidal volume, Frequency, I/E ratio; Peak airway pressure, Wavefrom(Pressure-time)

■ Respiratory modes: under Manual control or Automatic control, IPPV, SIGH, SIMV/f/2, SIPPV,

■ Tidal volume:0,50~1500mL

■ Respiratory frequency:2~99bpm

■ I:E:5:1~1:8 adjustable

■ PTRIG: -2~0kPa

■ High pressure limitation:2~6kPa

■ Low pressure limitation:0~2kPa

 

Circle Absorber Assembly

■ New launching integrated CO2 Absorber, could be high temperature 134℃sterilized.

Cup type Canister, around 2.5L, easily and fast change soda lime.

 

Anesthesia Vaporizer

■ High precise Anesthesia Vaporizer (Enflurane, Halothane, Isoflurane, Sevoflurane)

■ Sevoflurane adjustment scope;0~8% Vol;

Enflurane, Halothane, Isoflurane adjustment scope:0~5%Vol

■ Automatic compensation of flow, temperature and pressure

■ Self-lock

■ Volume: ≥250mL

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp