  • Parameters

  • Parameters

Technical Parameters

Main Unit:

Working modes: For the closed system, half-closed system and half-open system

Application: Adult and Pediatric

Low gas supply alarm: when Oz supply pressure is over low, the machine will arise > (longer than) 7 seconds audible alarm.

High pressure limitation: when airway pressure is higher than pre-set figure, the machine will automatically start protection function. The airway pressure will stop increasing (not increase any more) to keep patient safe.

Low pressure protection: when Oz gas supply pressure is lower than 0.1MPa,the machine will automatically cut off N20 supply.

When power supply fails, audible and visual alarms will arise. The machine will continuously work by battery.

O2 Flush: 25L/min~75L/min

Gas Supply: O2: 0.28MPa~0.6MPa N20: 0.28MPa~0.6MPa

Power supply: AC 220V, 50 Hz Built-in UPS power supply for backup.

Flowmeter:

02/N20 four-tube Flowmeter (0 ~ 1L/min 1 ~ 10L/min)

Linkage of Oz and N20, keep oxygen concentration over 25%


Anesthesia Ventilator:

Pneumatically driven and electrically control

Monitoring: Tidal volume, Frequency, MV, I/E ratio; Peak airway pressure, Oz concentration, Apnea. Waveform(Pressure-time), Waveform (Flow-time)

Working mode: Manual control or Automatic control

Respiratory modes: IPPV, SIGH, SIMV/f/2, SIPPV, PEEP(0.5kPa ~2 kPa) Optional: EtCOz

Tidal volume:0,50 ~ 1500mL

Respiratory frequency:2 ~ 99bpm

I:E:5:1 ~ 1:8 adjustable

MV: not lower than 16L/min

FiOz: 21 ~ 100%

PtriG: -2 ~ 0kPa

High pressure limitation:2 ~ 6kPa Low pressure limitation:0 ~ 2kPa
Circle Absorber:

New launching integrated COz Absorber, could be high temperature 134°C sterilized.

Cup type Canister, around 2.5L, easily and fast change soda lime.

 

 


Anesthesia Vaporizer:

High precise Anesthesia Vaporizer (Enflurane, Halothane, Isoflurane, Sevoflurane)

Sevoflurane adjustment scope: 0 ~ 8% Vol;
Enflurane, Halothane, Isoflurane adjustment scope: 0 ~ 5%Vol

Automatic compensation of flow, temperature and pressure

Self-lock and interlock

Volume: ≥250mL

 

Related Products

SMT-050DE Double Column Digital Radiography System (Electric)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

AED-5 Automated External Defibrillator

1. 2 languages to choose from (by end user) 2. Bluetooth for data transmission (standard) 3. Daily, weekly and monthly self test 4. Use of AED in pocket (does not need to be opened) 5. Extra pocket in the bag for first aid products 6. IPX55 water and dust resistant 7. 5 volume levels (by the end user) 8. Button for adult/child mode

SMT-40E Medical Ventilator

No external gas source can be independently long-term work (Bring your own air) The operator control panel is with clear LCD display. Easy to operate. Whole body is compact, easy to install on a ventilator tower crane, ambulance. Friendly interface, easy operation and intuitive. Offers three power: AC, Car Power, Built-in battery Self-powered support ventilator work more than two hours.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).