SM-P15A Multi-parameter Patient Monitor

Application Range: Adult/Pediatric/Neonatal/Medicine /Surgery/Operating Room/ICU/CCU
  • Parameters

Technical Specification

Application Range

Adult/Pediatric/Neonatal/Medicine /Surgery/Operating Room/ICU/CCU

 

Display

15” real color TFT screen

Resolution:1024×768

One alarm indicator(yellow/red)

One working indicator(green)

One battery charge stateindicator(green)

Three modes in accordance with the alarm state

 

Environment

Operating Environment :

Temperature: 0 ~ 40 ℃

Humidity: ≤85%

Altitude: -500~4600m

 

Transport and Storage Environment :

Temperature: -20~60 ℃

Humidity: ≤93%

Altitude: -500~13100m

 

Power Requirements

AC: 100 ~ 240V, 50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 5200mAh 11.1V lithium battery

4h operating afterf ull charge(one piece)

5min operating after low battery alarm

 

Dimension and Weight

Equipment: 300mm×286mm×155 mm(about); 4.5kg(about)

Package : 350mm ×380 mm × 300mm(about); 6.5kg(about)

 

Date Storage

Trend diagram/table: 7x24h

NIBP review: 400 events

Wave review: 100min

Alarm review: 100 alarm events

Support drug concentration titration analysis

 

ST Segment

ST Segment Range: -2.0mV ~ +2.0mV

Accuracy: 0.02mV

 

Pulse Rate

Range: 20 ~ 300bpm

Resolution: 1bpm

Precision: ±3bpm

 

ECG

5 Leads: RA, LA, LL, RL, V

Lead mode: Ⅰ,Ⅱ, Ⅲ, aVR, aVL, aVF, V Increase: ×250,×500,×1000, ×2000

Sensitivity: > 200 uV (Peak-to-peak value)

Input impedance: > 5 ( megohm )

Bandwidth: Surgery 1 ~ 20 Hz

Monitor 0.5 ~ 40 Hz

Diagnostic 0.05 ~ 130 Hz

CMRR 100dB

Polarization Voltage: ± 300mV

Baseline Recovering Time: After defibrillation< 3 seconds

Signal Range: 8 mV (Peak-to-peak value)

Calibrating Signal: 1mV, precision ±5%

Heart rate range:15-380bmp

Heart rate accuracy:+/-1%

 

RESP

Method: RA-LL impedance

Resp Impedance range: 0.3 ~ 3

Base Impedance range: 200 ~ 4000

Bandwidth: 0.1 ~ 2.5Hz

Resp rate: Adult 0 ~ 120BrPM

Neonatal/Pediatric 0 ~ 150BrPM

Resolution: 1BrPM

Precision: ±2 BrPM

Asphyxia Alarm: 10~40 seconds

 

NIBP

Method: Pulse wave oscillometry

Work mode: Manual/ Auto/ STAT

Measure interval of auto mode:

1,2,3,4,5,10,15,30,60,90,120,180, 240,480 minute(s)

Measuring Time of STAT Mode: 5 minutes

PR range: 30 ~ 250bpm

Measure & alarm range:

Adult

SYS 40 ~ 270mmHg

DIA 10 ~ 215mmHg

MEAN 20 ~ 235mmHg

Pediatric

SYS 40 ~ 200mmHg

DIA 10 ~ 150mmHg

MEAN 20 ~ 165mmHg

Neonatal

SYS 40 ~ 135mmHg

DIA 10 ~ 100mmHg

MEAN 20 ~ 110mmHg

Static pressure range: 0 ~ 300mmHg

Precision: ± 3mmHg

Pressure precision:

Max. average error: ±5mmHg

Max. standard deviation: ±8mmHg

Overvoltage protection:

Adult 300mmHg

Pediatric 240mmHg

Neonatal 150mmHg

 

SpO2

Range: 0 ~ 100%

Resolution: 1%

Precision: 70% ~ 100%: ±2 DIGIT 0% ~ 69%: ±no definition given

 

TEMP

Channel 2

Measure & alarm range: 0 ~ 50 ℃

Resolution: 0.1 ℃

Precision (no sensor): ±0.1 ℃

 

IBP(Optional)

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART 0 ~ 300 mmHg

PA -6 ~ 120 mmHg

CVP/RAP/LAP/ICP -10 ~ 40 mmHg

P1/P2 -10 ~ 300 mmHg

Press Sensor

Sensitivity 5 uV/V/mmHg

Impedance 300-3000

Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec.

 

CO2(Optional)

Side/Main stream

Warm-up time:when the ambient temperature is 25 ℃, the carbon dioxide curve(capnogram) can be displayed within 20/15 seconds, and all the specifications can be fulfilled within 2 minutes.

Measurement range:0-150mmHg, 0-19.7%,0-20kPa (at 760mmHg), atmospheric pressure provided by the host.

Resolution 0.1mmHg :0-69mmHg 0.25mmHg: 70-150mmHg

Precision 0-40mmHg: ±2mmHg

41-70mmHg: ±5%(reading)

71-100mmHg: ±8%(reading)

101-150mmHg:±10%(reading)

Respiratory rate range 0- 150 BPM

Respiratory rate accuracy: ±1 BPM

 

Standard Accessories

NIBP cuff & tube

ECG cable & electrodes

SpO2 sensor

TEMP probe

Lithium-ion battery

Power cable

Operator’s manual

 

Optional

Etco2

C.O.modular

BIS modular

IBP modular

Touch screen

Trolley bracket

Hanging bracket

Monitor recorder

Wifi

Related Products

SM-200V Patient Monitor

12.1” color TFT LCD screen( touchscreen is optional ) 8 waveform display,up to 12-lead ECG analysis Powerful calculation(Hemodynamic, Dose, Oxygenation, Ventilation) Pacemaker detection ST & arrhythmia analysis(17 types) SpO2 support PI, low perfusion 0.2% Night mode, standby mode, venipucture mode Various mounting solutions Wired/Wireless CMS, support HL7 protocol to HIS SpO2 pulse-tone modulation (Pitch Tone) MEWS(Modified Early Warning Score) Graphical & tabular trend review(480 hours), USB data output Rechargeable Lithium-Ion Battery 48 Hours full disclosure waveforms review & print for each patient

Leave A Message


    Products
    Contact
    WhatsApp
    Email