SMT-2A Infant Incubator

Microprocessor based servo controlled temperature system
Control modes: Air mode and baby skin mode
Humidity is adjustable continuously
Set temperature, air temperature, baby skin temperature, timer and heating power are displayed separately by LED
Integral timer to record therapy time
Self-testing function, various failure alarms by audible and visual
Alarm function: Power failure, Over temperature, Temperature deviation, Fan failure, Temperature sensor failure
>37°temperature set function
Triple protection for over temperature with separate cut off device, more safety system
The inclination of infant bed is adjustable
Single wall hood, 4 operating windows and 2 iris ports, 5 infusion seals
Independent locking device for front door
Connector, Oxygen inlet, 1 tray
  • Parameters

Technical Specification

 

Power requirement: AC220-230V/50Hz or AC110-120V, 50/60Hz, 850VA

Auxiliary power output: AC220-230V/50Hz, maximum current allowed: 1.6A

 

Incubator Module

Air temperature control range: 25.0°C-37.0°C (override mode 37.1°C-39.0°C, optional)

Baby temperature control range: 34.0°C-37.0°C (override mode 37.1°C-38.0°C, optional)

Temperature sensor display range: 5°C-65°C

Warm-up time (with the ambient temperature at + 22°C): No longer than 30 minutes

Accuracy of skin temperature sensor: within ± 0.2°C (optional)

Temperature Variation: ≤0.5℃

Difference between the air temperature at one point and the average air temperature: No greater than 0.8°C

Difference between the average air temperature and the control temperature: No greater than 1.0°C

Temperature uniformity (mattress horizontally placed): No greater than 0.8°C

Temperature uniformity (mattress titled): No greater than 1.0°C

Mattress size: 633mm×342mm

Weight display accuracy:±1% (optional)

Inclination of the bassinet: ±12°

Environmental noise in the compartment in incubator mode:

Under stable temperature ≤ 45dB(A)

Under other conditions ≤ 50dB(A)

Failure alarm: power failure alarm, fan motor alarm, sensor alarm, deviation alarm, over-temperature alarm, system alarm and so on

CO2 concentration in the compartment: Lower than 0.5% when the CO2 mixture is pumped in at the speed of 750 ml/min at 10 cm above the center of the mattress

Air flow speed above the mattress: no greater than 0.35 m/s

 

Environmental Requirement

Operating range: 20°C-30°C

Relative Humidity: 30%RH-75%RH

Atmospheric pressure range:800hPa-1060hPa

Ambient air flow speed: < 0.3m/s

 

Product Dimension

Dimension:

L1170mm × W620mm × H1620mm (with stand), L1170mm × W620mm × 1550mm-1700mm (with VHA stand)

Distance from the bassinet to the floor:

980mm

950mm-1100mm

Hood size: L 856mm×400mm×454mm

Wheel size(diameter): 100mm

Weight: 103kg (with stand), 113kg (with VHA stand)

 

Function Introduction

Two control modes: air mode and baby mode controlled by micro-computer

Set temperature, air temperature and baby temperature are displayed separately

Passive humidification

Inclination if bassinet is adjustable

Independent over-temperature protection system

Multiple failure alarm indications

Independent locking device for the front door

RS-232 connector for data output

Oxygen input interface, Oxygen supply system

Low noise DC motor

Air filter system able to get filtration of most common dust in the air circulation and easy to replace

The pressure difference between the spiral duct and the tributary centrifugal fan ensures that fresh air is always inhaled

 

Standard Configuration

Main body (including baby compartment, base, controller, I.V. pole and tray), stand

 

Optional Configuration

>37°C override mode, VHA stand, weighing system

Related Products

SMT-050DE Double Column Digital Radiography System (Electric)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

AED-5 Automated External Defibrillator

1. 2 languages to choose from (by end user) 2. Bluetooth for data transmission (standard) 3. Daily, weekly and monthly self test 4. Use of AED in pocket (does not need to be opened) 5. Extra pocket in the bag for first aid products 6. IPX55 water and dust resistant 7. 5 volume levels (by the end user) 8. Button for adult/child mode

SMT-40E Medical Ventilator

No external gas source can be independently long-term work (Bring your own air) The operator control panel is with clear LCD display. Easy to operate. Whole body is compact, easy to install on a ventilator tower crane, ambulance. Friendly interface, easy operation and intuitive. Offers three power: AC, Car Power, Built-in battery Self-powered support ventilator work more than two hours.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp
    Email