SMT-1900DU Ophthalmic A/B Mode Ultrasound Scanner

10.4 inch high resolution LCD screen,
Menu operation Language: Chinese/English.
Double probe sockets:
A mode probe: 10MHz probe with fixation light.
B mode probe: 10MHz transducer.
Display mode: B, B/B, 4B, B/A, A
Gains range: 0--120dB.
Dynamic range: 30-100dB, visual and adjustable.
Gray: 256.
Intelligent TGC adjustment: 8 segments.
Report function: print screen, IOL report, case report with picture, etc.
  • Parameters

Technical Specification

A scan

Resolution: 0.01mm

Gain adjustable: 0-120dB

Measurement range: 15-40mm(1640m/s)

Accuracy: ±0.1mm

Measuring parameter: ACD, LENS, Vitreous body Length, axial length.

Eye mode: normal/aphakia/dense cataract/PMMA, Acrylic & Silicon for Pseudo

Phakic eyes

Measuring Mode: Contact and Immersion, automatic and manual.

Calculation: std. deviation, average, automatical measuring 10 groups and average,

accompany waveform, results correctable.

IOL Formula: SRK-II, SRK-T, BINKHORST,HOLLADAY, HOFFER-Q, HAIGIS

 

B scan

Scan mode: High accuracy stepping motor drive sector scan.

Scan Angle: 53°.

Display Depth: 0~56mm

Gray: 256.

Frame frequency: 10frames/s.

depth seletion: 8.

Frame correlation: 4.

Edge enhancement:4.

Compression Curve: 4

Post-processing: 8

100 frames permanent image storage.

Cine loop: 256 frames,can measure the playback image.

Disk management.

General Measurement: multi-electronic-rule to measure distance, circumference,

area(trace method, ellipse method),volume (ellipse method), angle , histogram,

profile , stenosis and curvature etc.

 

Specification

Power supply : 100-240V~ 1.2-0.6A

Frequency:50-60Hz

Adapter output: DC12.8V 3.0A

 

Related Products

SMT-10AP Bio&Pachy Meter

5.7"color LED touch screen, more convenient for your operation. Immersion&contact methods, precise measurement. Built-in thermal printer, realize print anytime. I-station software enable massive storage, generate and print report. Sensitive, accurate measurement, show 10 groups with deviation meanwhile. With IOP(intraocular pressure) adjustment after get tonometer measurement results

SMT-10A Biometer

5.7"color LED touch screen, more convenient for your operation. Immersion&contact methods, precise measurement. Built-in thermal printer, realize print anytime. I-station software enable massive storage, generate and print report. Sensitive, accurate measurement, show 10 groups with deviation meanwhile. With IOP(intraocular pressure) adjustment after get tonometer measurement results

SMT-2000U Ophthalmic A/B Scanner

15 inch LED touch screen, all-in-one, pretty, portable Integrated Image Capture Integrated Patient Database Integrated Report Editor Can work with battery

Leave A Message


    Products
    Contact
    WhatsApp
    Email