SM-E70 Series Electrolyte Analyzer

Automatic electric potential tracking and correcting software to ensure the stable performance.
Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.
Real-time diagnostis of system working status. Waste liquid automatic detection and alarming.
Automatic calibration and two-point correction to adjust slope and intercept.
Wave flushing method and direct flushing pipe method to avoid block and crossed contamination.
Power failure protection for data storage up to 20000 results.
Minimum consumption, reduce consumable cost.
  • Parameters

Technical Specification

Model Suntra
SM-E70
Principle ion selecive electrode(ISE)
Sample position 39 positions (including 5 emergency and 4 functional positions)
Barcode scanning Built-in or external barcode scanner (optional)
Reagent Identification Radio Frequency Identification (RFID) (optional)
Detection speed ≤45 seconds
Paramete K, Na, Cl, iCa, nCa, TCa, pH, Li, Mg, CO2, AG
Sample type serum, plasma, whole blood and dilute urine
Sample volume 120μL
Sample loading Manual loading/auto loading
Fully automatic sample tray Original tube sample tray/automatic sample tray (optional)
Liquid level detection Original tube supports liquid level detection function
Reagent Specifications Cal A 350ml/Cal B 350ml
Reagent storage temperature Room temperature
Calibration method Built-in master calibration curve, 2-point calibration
Automatic calibration time Automatic calibration at startup
Built-in quality control Comes with internal calibration solution C-2, single-point and two-point calibration supported
Storage 10000
Data transmission LIS
External interface RS232
Printer Built-in thermal printer
Screen size 5.4 inches screen
Dimension(mm)(L*W*H) 380mm(L)*270mm(W)*400mm(H)
Weight 8kg

 

Measure Data

Items Measuring Range Resolution Measuring Precision(CV%)
K+ 0.50-20.00mmol/L 0.01mmol/L ≤1.5%
Na+ 15.0-200.0mmol/L 0.1mmol/L ≤1.5%
Cl- 15.0-200.0mmol/L 0.1mmol/L ≤1.5%
Ca++ 0.10-6.00mmol/L 0.01mmol/L ≤2.0%
pH 4.00-9.00pH 0.01pH ≤2.0%
Li+ 0.10-6.00mmol/L 0.01mmol/L ≤3.0%
Mg++ 0.10-4.00mmol/L 0.01mmol/L ≤3.5%
TCO₂ 2.0-70.0mmol/L 0.1 mmol/L ≤3.5%

 

Model No Configuration
A K Na Cl
B K Na Cl TCO₂AG
C K Na Cl iCa nCa TCa pH
D K Na Cl iCa nCa TCa pH TCO₂ AG
F K Na Cl Li
H K Na Cl iCa nCa TCa pH Li
I K Na Cl iCa nCa TCa pH Li TCO₂AG
K K Na Cl iCa nCa TCa pH Mg
L K Na Cl iCa nCa TCa pH Mg TCO₂AG
M K Na Cl iCa nCa TCa pH Mg Li TCO₂AG
N K Na Cl iCa nCa TCa pH Mg

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp
    Email