SM-1300IIA2 Biosafety Cabinet

Class II Biosafety Cabinet, air flow mode: 30% efflux, 70% loop.
The outer box is made of high-quality cold-rolled steel plate and electrostatic sprayed, three sides of the operation area adopt integrated stainless steel structure. The internal cleanable parts are treated with 10mm large rounded corners for easy cleaning.
High quality fan, wind speed can be automatically adjusted, low noise.
Equipped with high sensitivity, high precision breeze speed sensor, non-pressure difference sensor, real and real-time monitoring of wind speed.
Independently developed control software system, obtained the national software copyright certificate. LCD screen can display the working area temperature, air flow velocity, etc., can adjust the parameter settings, blue screen digital indication of the parameter values, password modification program Settings, to prevent misoperation.
  • Parameters

Features

Class II Biosafety Cabinet, air flow mode: 30% efflux,70% loop.

Conform to Pharmaceutical Industry Standards of the People’s Republic of China《YY 0569-2011》.

The outer box is made of high-quality cold-rolled steel plate and electrostatic sprayed, three sides of the operation area adopt integrated stainless steel structure. The internal cleanable parts are treated with 10mm large rounded corners for easy cleaning.

Equipped with two HEPA filters, filter efficiency: ULPA@0.12μm99.9995%, the filter membrane is made of borosilicate glass fiber without partition.

High quality fan, wind speed can be automatically adjusted, low noise.

Equipped with high sensitivity, high precision breeze speed sensor, non-pressure difference sensor, real and real-time monitoring of wind speed.

Independently developed control software system, obtained the national software copyright certificate. LCD screen can display the working area temperature, air flow velocity, etc., can adjust the parameter settings, blue screen digital indication of the parameter values, password modification program Settings, to prevent misoperation.

Filter alarm: real-time bar code type display filter remaining life, sound and light alarm prompt replacement.

Equipped with height limit/low limit alarm device, sound and light remind when the moving glass door exceeds or falls below the specified value.

The unique negative pressure anti-leakage design, the working area is surrounded by negative pressure on all sides, zero leakage to ensure the cleanliness of the operating area.

Front window integrated sliding door, can be positioned arbitrarily, and UV lamp can be opened when completely closed.

The front window glass door is made of 6mm thick safety tempered glass.

Chain protection design: when the front window is opened, the germicidal lamp is turned off, the lamp and the fan are automatically started, the operation is convenient.

UV lamp has reservation and timing functions.

Equipment includes one spare socket.

 

Technical Specification

Item/Model SM-1300ⅡA2
Cleanliness Level HEPA:ISO Class 4(Class10)
Supply air velocity 0.33m/s±0.025
Inflow air velocity 0.53m/s±0.025
Noise ≤67dB
Power / Maximum power consumption AC, 220V/50HZ / 1.5KW
Biosecurity personnel protection All impact sampler samples CFU≤10, Slit sampler CFU≤5
Product protection All petri dish samples CFU≤5
Cross-contamination protection All petri dish samples CFU≤2
Dimension of working area 1300*520*640 mm
Overall dimension 1465*760*2200 mm
Illumination ≥900LX
Weight 260kg
Number of Operator 1-2
Draft direction Top

 

Related Products

SMT-050DE Double Column Digital Radiography System (Electric)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

AED-5 Automated External Defibrillator

1. 2 languages to choose from (by end user) 2. Bluetooth for data transmission (standard) 3. Daily, weekly and monthly self test 4. Use of AED in pocket (does not need to be opened) 5. Extra pocket in the bag for first aid products 6. IPX55 water and dust resistant 7. 5 volume levels (by the end user) 8. Button for adult/child mode

SMT-40E Medical Ventilator

No external gas source can be independently long-term work (Bring your own air) The operator control panel is with clear LCD display. Easy to operate. Whole body is compact, easy to install on a ventilator tower crane, ambulance. Friendly interface, easy operation and intuitive. Offers three power: AC, Car Power, Built-in battery Self-powered support ventilator work more than two hours.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp
    Email