TopPette Mechanical Pipettes

Light weight, ergonomic, low force design
Digital display clearly reads volume setting
The pipettes cover volume range of 0.1uL to 10mLEasy to calibrate and maintain with tool supplied
Design helps avoid repetitive strain injuries
Each pipette supplied with individual test certificate
The lower section can be autoclaved
  • Parameters

Technical Specification

Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error

(Inaccuracy)

Maximum permissible random error

(Imprecision)

μL μL μL % μL % μL
 

0.1-2.5

 

0.05

2.5 ±2.50 ±0.0625 ±2.00 ±0.05
1.25 ±3.00 ±0.0375 ±3.00 ±0.0375
0.25 ±12.00 ±0.03 ±6.00 ±0.015
 

0.5-10

 

0.1

10 ±1.00 ±0.1 ±0.80 ±0.08
5 ±1.50 ±0.075 ±1.50 ±0.075
1 ±2.50 ±0.025 ±1.50 ±0.015
 

2-20

 

0.5

20 ±0.90 ±0.18 ±0.04 ±0.08
10 ±1.20 ±0.12 ±1.00 ±0.1
2 ±3.00 ±0.06 ±2.00 ±0.04
 

5-50

 

0.5

50 ±0.60 ±0.3 ±0.30 ±0.15
25 ±0.90 ±0.225 ±0.60 ±0.15
5 ±2.00 ±0.1 ±2.00 ±0.1
 

10-100

 

1

100 ±0.80 ±0.8 ±0.15 ±0.15
50 ±1.00 ±0.5 ±0.40 ±0.2
10 ±3.00 ±0.3 ±1.50 ±0.15
 

20-200

 

1

200 ±0.60 ±1.2 ±0.15 ±0.3
100 ±0.80 ±0.8 ±0.30 ±0.3
20 ±3.00 ±0.6 ±1.00 ±0.2
 

50-200

 

1

200 ±0.60 ±1.2 ±0.15 ±0.3
100 ±0.80 ±0.8 ±0.30 ±0.3
50 ±1.00 ±0.5 ±0.40 ±0.2
 

100-1000

 

5

1000 ±0.60 ±6 ±0.20 ±2
500 ±0.70 ±3.5 ±0.25 ±1.25
100 ±2.00 ±2 ±0.70 ±0.7
 

200-1000

 

5

1000 ±0.60 ±6 ±0.20 ±2
500 ±0.70 ±3.5 ±0.25 ±1.25
200 ±0.90 ±1.8 ±0.30 ±0.6
 

500-5000

 

50

5000 ±0.50 ±25 ±0.15 ±7.5
2500 ±0.60 ±15 ±0.30 ±7.5
500 ±0.70 ±3.5 ±0.30 ±1.5
 

1000-5000

 

50

5000 ±0.50 ±25 ±0.15 ±7.5
2500 ±0.60 ±15 ±0.30 ±7.5
1000 ±0.70 ±7 ±0.30 ±3
 

1000-10000

 

100

10000 ±0.60 ±60 ±0.20 ±20
5000 ±1.20 ±60 ±0.30 ±15
1000 ±3.00 ±30 ±0.60 ±6
2000-10000

Do not apply to

MicroPette plus

100 10000 ±0.60 ±60 ±0.20 ±20
5000 ±1.20 ±60 ±0.30 ±15
2000 ±3.00 ±60 ±0.60 ±12
*2000-20000 100 2000 ±6.00 ±120 ±3.00 ±60
10000 ±1.20 ±120 ±0.60 ±60
20000 ±0.60 ±120 ±0.30 ±60

 

8-channel Adjustable Volume Pipettes
Volume

Range

 

IncrementTest Volume

Maximum permissible

systematic error (Inaccuracy)

Maximum permissible

random error (Imprecision)

% μL % μL
 

0.5-10μL

 

0.1μL

10μL ±1.50 ±0.15 ±1.50 ±0.15
5μL ±2.50 ±0.125 ±2.50 ±0.125
1μL ±4.00 ±0.04 ±4.00 ±0.04
 

5-50μL

 

0.5μL

50μL ±1.00 ±0.5 ±0.50 ±0.25
25μL ±1.50 ±0.375 ±1.00 ±0.25
5μL ±3.00 ±0.15 ±2.00 ±0.1
 

10-100μL

 

1μL

100μL ±0.80 ±0.8 ±0.30 ±0.3
50μL ±1.00 ±0.5 ±0.80 ±0.4
10μL ±3.00 ±0.3 ±2.00 ±0.2
 

50-300μL

 

5μL

300μL ±0.70 ±2.1 ±0.25 ±0.75
150μL ±1.00 ±1.5 ±0.50 ±0.75
50μL ±1.50 ±0.75 ±0.80 ±0.4

12-channel Adjustable Volume Pipettes

 

12-channel Adjustable Volume Pipettes
Volume

Range

 

Increment Test Volume

Maximum permissible

systematic error (Inaccuracy)

Maximum permissible

random error (Imprecision)

% μL % μL
 

0.5-10μL

 

0.1μL

10μL ±1.50 ±0.15 ±1.50 ±0.15
5μL ±2.50 ±0.125 ±2.50 ±0.125
1μL ±4.00 ±0.04 ±4.00 ±0.04
 

5-50μL

 

0.5μL

50μL ±1.00 ±0.5 ±0.50 ±0.25
25μL ±1.50 ±0.375 ±1.00 ±0.25
5μL ±3.00 ±0.15 ±2.00 ±0.1
 

10-100μL

 

1μL

100μL ±0.80 ±0.8 ±0.30 ±0.3
50μL ±1.00 ±0.5 ±0.80 ±0.4
10μL ±3.00 ±0.3 ±2.00 ±0.2
 

50-300μL

 

5μL

300μL ±0.70 ±2.1 ±0.25 ±0.75
150μL ±1.00 ±1.5 ±0.50 ±0.75
50μL ±1.50 ±0.75 ±0.80 ±0.4

 

 

Fixed Volume Pipettes
Volume

Range

 

Increment Test Volume

Maximum permissible

systematic error (Inaccuracy)

Maximum permissible

random error (Imprecision)

% μL % μL
5μL 5μL ±1.3 ±0.065 ±1.2 ±0.06
10μL 10μL ±0.8 ±0.08 ±0.8 ±0.08
20μL 20μL ±0.6 ±0.12 ±0.5 ±0.1
25μL 25μL ±0.5 ±0.125 ±0.3 ±0.075
50μL 50μL ±0.5 ±0.25 ±0.3 ±0.15
100μL 100μL ±0.5 ±0.5 ±0.3 ±0.3
200μL 200μL ±0.4 ±0.8 ±0.2 ±0.4
250μL 250μL ±0.4 ±1.0 ±0.2 ±0.5
500μL 500μL ±0.3 ±1.5 ±0.2 ±1.0
1000μL 1000μL ±0.3 ±3.0 ±0.2 ±2.0
2000μL 2000μL ±0.3 ±6.0 ±0.15 ±3.0
5000μL 5000μL ±0.3 ±15 ±0.15 ±7.5

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp