SMT-V03 Vascular Doppler (Unidirectional/Bidirectional)

Detection of blood flow in superficial and peripheral microvascular arterial/venous vessels of the human body aided with an 8.0 MHz bidirectional blood flow probe.
2.4" TF'T display capable of displaying blood flow waveforms, peak average blood flow rate
Bidirectional blood flow detector can store 50 sets of blood flow velocity and waveform data records, blood flow waveform smoothing processing and regular processing mode.
Built-in data interface, with optional special PC software to transfer data to PC for analysis, storage and printing
Built-in high-quality speakers. Clear and loud output sound.
Equipped with a freeze function key, which can always freeze the blood flow waveform graph that needs to be detected
SMT-V03 (bi-directional model) bi-directional blood flow waveform includes separated mode and combined flow rate graphs
SMT-V03 (unidirectional model) unidirectional blood flow waveform.
  • Parameters

Technical Specification

External output: Loudspeaker

Emission waveform: sine wave

Ultrasonic frequency:8.0MHz±10%

Ultrasonic power average sound intensity: ≤50mW/cm2

Velocimetric range: 40 to 200 cm/s.

Speed measurement error: ≤20%(relative error)

Gain adjustment: automatic gain

System gain:> 100dB

Display mode: 320*240 dot matrix color display

Unidirectional Waveform

Power supply mode: AC/DC operation.

Power consumption of the whole machine: <20W

Built-in 7.4V/900mAh rechargeable lithium battery

Working indication: working indicator and power indicator

Continuous working time: ≥8 hours

Working environment.

Temperature: +5℃~+40℃; Humidity: <80%; Atmosphere pressure: 86kPa~106kPa

Transport and storage environment.

Temperature: -10℃~+55℃; Humidity: <80%; Atmospheric pressure: 86kPa- 106kPa

Unidirectional model: detects systolic blood flow velocity (widely used) analyzes systolic blood flow status, determines whether there is obstruction, and determines arteriovenous position during surgery;

Bidirectional models: not only for testing the elasticity of blood vessels and analyzing and judging the state of the vessel wall, but for giving feedback on the state of cardiovascular function.

Related Products

SMT-V03 Vascular Doppler (Unidirectional/Bidirectional)

Detection of blood flow in superficial and peripheral microvascular arterial/venous vessels of the human body aided with an 8.0 MHz bidirectional blood flow probe. 2.4" TF'T display capable of displaying blood flow waveforms, peak average blood flow rate Bidirectional blood flow detector can store 50 sets of blood flow velocity and waveform data records, blood flow waveform smoothing processing and regular processing mode. Built-in data interface, with optional special PC software to transfer data to PC for analysis, storage and printing Built-in high-quality speakers. Clear and loud output sound. Equipped with a freeze function key, which can always freeze the blood flow waveform graph that needs to be detected SMT-V03 (bi-directional model) bi-directional blood flow waveform includes separated mode and combined flow rate graphs SMT-V03 (unidirectional model) unidirectional blood flow waveform.

SMT-V2 Ultrasonic Vascular Doppler Detector

Detection of blood flow conditions in superficial and peripheral micro vascular arterie/venules of the human body, aided by an 8.0 MHz blood flow probe: LED screen display can display blood flow velocity value in real time; Built-in high-capacity rechargeable battery to meet long working hours; Handheld device.compact and easy to use; Built-in high-quality loud speaker. Clear and loud output sound.

Leave A Message


    Products
    Contact
    WhatsApp
    Email