Technical Specification
| Self-test | Daily, Weekly, Monthly |
| Mode | Adult, Child |
| Waveform | Biphasic truncated exponential |
| Energy | 200-Joules max. |
| Energy Sequence | Child Mode: 50.50.75 Joules
Adult Mode: 150.150.200 Joules |
| Charge time
(New, at 25℃) |
Less than 8 sec. to 150J
Less than 12 sec. to 200J |
| Voice Prompt | Extensive voice prompt |
| Visual Indicators | LED prompts |
| Control | Three buttons: ON/OFF, Select Mode, Shock |
| ECG storage | 1,800 events (upgradable to 65 hours) |
| Data transmission | Bluetooth |
| Power | Battery non-rechargeable |
| Type | 12V, 2800mAh Li-Mn02 Cell |
| Operating Temperature | 0℃ to 40℃ |
| Operating Humidity | Relative humidity between
30% and 95%(non-condensing) |
| Storage Temperature (without battery) | -20℃ to 55℃ |
| Storage Humidity(without battery) | Up to 93%〔non-condensing〕Physical |
| Storage Temperature (Disposable Pad) | 0~50℃ |
| Dimensions | Depth(D): 80mm
Width(W): 240mm Length(L): 300mm |
| Weight (with battery) | 1.9Kg (4.2 Pounds) |
| Standard Accessories
|
Battery:
CR123A-4×22.8Ah 12Volt non-rechargeable battery Disposable Pad: Designed for external defibrillation, non-invasive pacing,synchronized cardioversion, and monitoring of adults and children weighing more than 20 kg(55 Ibs). Carry Case: Reflective sign, Soft Hand, Speaker protection, Transparent panel, Socket Protector |
Data Communication
The AED memory software assists the AED in receiving data sent via Bluetooth. The AED Memory Software supports reading and setting ECG waves, setting the AED language, reading, analysing, and deleting memory data can also be performed with the our company AED Memory Software.
Case Management
Our company AED storage software makes the selected data file a case record and stores cases in the database ACCESS. Case management supports importing and deleting data that can respond to the ECG waveform of the data file by selecting cases.
Memory Playback
The interface displays status information recorded during AED operation, including type, event time, description, and waves. Event types include: Power On Event, Self Test Event, Analysis Event, Charge Event, Discharge Event, CPR start event, CPR stop event. The event time displayed indicates when the event occurred. The description displays the parameter information. “OHM” represents the detected impedance of the patient.
The parameter “Pxower”stands for the voltage of the completed charge; “Shock required” means that a shock is recommended after the analysis is complete “No shock required” means that no shock is recommended after the analysis.
ECG
Waveform gain can be set to 5mm/mv, 10mm/mv, 20mm/mv; Waveform speed can be set to 12.5 mm/s, 25 mm/s, 50 mm/s.
Can preview the selected page and print basic information.