SM-8000D Multiparameter Patient Monitor

14”TFT LCD screen
  • Parameters

Technical specification

Application Range

Adult/Pediatric/Neonatal/Medicine /Surgery/Operating Room/ICU/CCU

 

Display

14”TFT LCD screen

Resolution: 1366*768

 

Environment

Working Environment Conditions

Temperature: Working temperature 0 - 40 ℃ Humidity: Working humidity ≤ 85 %

Shipping and Storage Conditions :

Temperature:

Transportation and storage temperature -20 - 60 ℃

Humidity:

Transportation and storage humidity ≤ 93 %

 

Electrical Specifications

Power supply voltage: AC 100~240V

AC, power frequency: 50/60Hz,

maximum input power 70VA

Fuse is F2AL 250V

Working method: continuous work Built-in lithium battery: d.c11.1V not less than 2000mA, working time not less than 2 hours

 

Dimension and Weight

Equipment : 4.1kg(about)

Package : 380*350*300mm(about) ; 5.5kg(about)

 

ECG

Gain: X0.25, X0.5, X1, X2, Auto

Waveform speed: 12.5mm/s, 25mm/s, 50mm/s

Sensitivity>200uV (peak-to-peak)

bandwidth:

Diagnostic mode: 0.05~130Hz

Monitoring mode: 0.5~40Hz

Operation mode: 1~20Hz

Common Mode Rejection Ratio:

Diagnostic mode: >90dB

Monitoring mode: >100dB

Operation mode: >100dB

Electrode polarization voltage: ±300mV

Input impedance≥5M

DC bias voltage: ±300mV

Calibration signal: 1mV (peak-to-peak), accuracy ±5%

ST segment detection measurement:

Measurement range: -2.0mV~+2.0mV

Measurement accuracy: within the range of -0.8mV~+0.8mV, the measure ment error is ±0.02mV or ±10%, whichever is greater, other ranges are undefined

 

Trend Data Length

School limit list: 400 groups

Waveform playback : 6000 seconds

Trend table : 7 days

Trend graph : up to 7 days

Alarm review : 60 groups

 

ST Segment

Maximum upper limit 2.0mv

Minimum lower limit -2.0mv

Single adjustment amount 0.1mv

 

NIBP

Measuring Range and Precision Range

Adult Systolic blood pressure 40~270mmHg

Diastolic blood pressure 10~215mmHg

Mean blood pressure 20~235mmHg

Static pressure range 0~300mmHg

Static pressure precision ±3mmHg

Pressure precision:

Max. average error: ±5mmHg;

Max. standard deviation: 8mmHg

 

SpO2

Measuring range 0~100%

Resolution 1%

The accuracy is within the range of 70% to 100%, and the measurement error should be ±2%;

In the range of 0% to 69%, the measurement error is undefined

 

Pulse Rate

Measuring range 30~300bpm

Resolution 1bpm

Accuracy ±3bpm

Update time 1s

 

Heart Rate

Adult 15 to 300bpm (beats/minute)

Neonatal/Child 15 to 350 bpm (beats/minute)

Accuracy ±1% or ±1bpm, whichever is greater

Respiration Rate

Adult 0~120BrPM

Children and neonates 0 to 150 BrPM In the range of 7BrPM~120BrPM, the measurement error should be ±2BrPM.

Errors in other ranges are undefined

 

Temperature

Range 0~50C

Resolution 0.1C

Accuracy ± 0.1C (excluding sensor error)

 

Standard Accessories

NIBP cuff & tube

ECG cable & electrodes

SpO2 sensor

TEMP probe

Lithium-ion battery

Power cable

Operator’s manual

 

Optional

Etco2 (Optional)

Dual IBP (Optional)

Nellcor Spo2 (Optional)

Touch Screen (Optional)

Monitor Recorder(Optional)

 

Related Products

SM-200V Patient Monitor

12.1” color TFT LCD screen( touchscreen is optional ) 8 waveform display,up to 12-lead ECG analysis Powerful calculation(Hemodynamic, Dose, Oxygenation, Ventilation) Pacemaker detection ST & arrhythmia analysis(17 types) SpO2 support PI, low perfusion 0.2% Night mode, standby mode, venipucture mode Various mounting solutions Wired/Wireless CMS, support HL7 protocol to HIS SpO2 pulse-tone modulation (Pitch Tone) MEWS(Modified Early Warning Score) Graphical & tabular trend review(480 hours), USB data output Rechargeable Lithium-Ion Battery 48 Hours full disclosure waveforms review & print for each patient