    ■ Integrated design, compact structure, fine and elegant
    ■ Menu-driven management system, expanding the use of space
    ■ With Output port for Anesthesia Information Management System
    ■ 10.4”colourful TFT+high-luminance LCD Display
    ■ With O2 concentration continuously monitoring function
    ■ Optional: a) Et CO2 b)AGSS
    Feature

Specifications:

Main unit

■ Working modes: For the closed system, half closed system and half open system

■  Application: Adult and Pediatric

■ Low gas supply alarm: when O2 supply pressure is over low,

the machine will arise > (longer than) 7 seconds audible alarm.

■ High pressure limitation: when airway pressure is higher than pre-set figure, the machine will automatically start protection function. The airway pressure will stop increasing (not increase any more) to keep patient safe.

■  Low pressure protection: when O2 gas supply pressure is lower than 0.1MPa,the machine will automatically cut off N2O supply.

■  When power supply fails, audible and visual alarms will arise. The machine will continuously work by battery.

■  Respiratory loops are available.

■  O2 Flush: 25L/min~75L/min

■  Gas Supply: O2: 0.28MPa~0.6MPa  N2O: 0.28MPa~0.6MPa  Air: 0.28MPa~0.6MPa

■  Power supply: AC 220V, 50 Hz Built-in UPS power supply for backup.

 

Flow Meter

■  O2/N2O/Air six-tube Flowmeter (0~1L/min 1~10L/min )

■  Linkage of O2 and N2O, keep oxygen concentration over 25%

 

Anesthesia Ventilator

■  Bellow for Adult 1 piece   Bellow for Pediatric 1 piece

■  Pneumatically driven and electrically control

■  Monitoring: under Manual control or Automatic control, Tidal volume(using differential pressure flow sensor), Frequency, I/E ratio; Peak airway pressure,

Wavefrom(Pressure-time),Wavefrom(Flow-time)

■ Respiratory modes: IPPV, SIGH, SIMV/f/2, SIPPV, PEEP(0.5~2kPa)

■ Tidal volume:0,50~1500mL( with tidal volume preset function)

■  Frequency: 2~99bpm

■ I:E:5:1~1:8 (continuously adjustable)

■ PTRIG: -2~0kPa

■ High pressure limitation:2~6kPa

■ Low pressure limitation:0~2kPa

 

Circle Absorber Assembly

■ New launching integrated CO2 Absorber, could be high temperature 134℃sterilized.

Cup type Canister, around 2.5L, easily and fast change soda lime.

 

Anesthesia Vaporizer

■ High precise Anesthesia Vaporizer (Enflurane, Halothane, Isoflurane, Sevoflurane)

■ Sevoflurane adjustment scope:  0~8% Vol

Enflurane, Halothane, Isoflurane adjustment scope:0~5%Vol

■ Automatic compensation of flow, temperature and pressure

■ Self-lock and interlock

■ Volume: ≥250mL

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).