Performance features
CUT MODE
PURE CUT
A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis.
BLEND 1
Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.
BLEND 2
The mode is used for vaporization of prostatic tissue or any fat tissue. The higher output wattage gives fast cutting effect of the tissue.
BLEND 3
It is used for major coagulation in major surgery, with some cutting functions.
ENDO CUT
The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode.
COAG MODE
SPRAY
Spray output is made for direct coagulation at the tissue with spark. above spark does not give any cutting effect as its CREST FACTOR is high.
FORCCE
This mode is greater degree of homeostasis and covers all demands of standard coagulation. This produce the fine attune waveform that creates superficial resistance in the tissue resulting in superior coagulation, where the tissue destroyed by hyper evaporation. This give surgeons the ability to remove surface structures without damaging deeper or peripheral tissues and to cauterize large surface areas quickly when required.
DESICATE
Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries it ensures pinpoint desiccation with less destruction of peripheral tissue.
BIPOLAR MODE
BI-COAG1
For highly precise control over coagulation process and privations of carbonization.
BI-COAG2
This bipolar technology nearly eliminate excessive current even during precision cutting in minute tissue structure
Rated output power:
CUT MODE
Pure cut:1W~350W (Max. 400W, load 500 Ω);
Blend cut 1:1W~250W (load 500 Ω);
Blend cut 2: 1W~200W (load 500 Ω);
Blend cut 3: 1W~150W (load 500 Ω);
ENDO CUT: 99%
COAG MODE
Spray coagulation:1W~80W (load 500 Ω);
Force coagulation: 1W~120W (load 500 Ω);
Desicate coagulation:1W~120W (load 500 Ω);
BIPOLAR
BI-COAG1: 1W~80W (load 100 Ω);
BI-COAG2:1W~100W (load 100 Ω);
Power consumption of the whole machine: ≤ 1100VA. (cut function 350W);
Default Program Modes indication:
0: Open surgery
1: Cut and coagulation alternate output, EMR
2: Pulse cut mode under intestinal ESD
3: Pulse cut mode under Subesophageal ESD
4: Pulse cut mode under Subgastric ESD, ERCP
5: Variable pulse
6: Fine surgery
7: Laparoscopic surgery
8: Monopolar underwater cut
9: Standard procedure
Normal operation
Ambient temperature range: 5 ℃~40 ℃;
Relative humidity range: ≤ 80%;
Atmospheric pressure range: 86.0~106.0kPa;
Power supply: 220V±10%, 50±1Hz; or 110V±10%, 60±1Hz
Working frequency: 416kHz;
Transportation and storage
Ambient temperature range: – 40 ℃~55 ℃;
Relative humidity range: ≤ 95%;
Atmospheric pressure range: 500hPa~1060hPa.
Configuration List
| Main unit | 1 PC□ |
| Disposable hand switch | 5PCS□ |
| Disposable neutral plate | 5PCS□ |
| Disposable neutral plate cable | 1 PC□ |
| Bipolar forceps | 1 PC□ |
| Bipolar forceps cable | 1 PC□ |
| Monopolar double foot switch | 1 PC□ |
| Bipolar single foot switch | 1 PC□ |
| Gastroscope high-frequency cable | 1 PC□ |
| Laparoscopy high-frequency cable | 1 PC□ |
| Power cable | 1 PC□ |
| GBXP5*20(5A) Fuse | 2PCS□ |
| PACKING LIST | 1 PC□ |
| USER’S MANUAL | 1 PC□ |
| WARRANTY CARD | 1 PC□ |
| QUALITY CARD | 1 PC□ |