SM-530WK Automatic Washer-Disinfector

Equipment category: fixed type
Outer box size: 1270 * 1000 * 2020 (L * W * H)
Cleaning compartment size: 693 * 828 * 935 (L *W * H)
Total volume: 536L
Power supply: 380V, 50Hz
Power: 40kVA
Environmental temperature: 5 ℃~40 ℃
Relative humidity: ≤ 80%
Atmospheric pressure range: 70kPa~106kPa
Water supply pressure: 0.2MPa~0.5MPa
Inlet water temperature: 5 ℃~40 ℃
Work cabin material: stainless steel 304
Load frame trolley material: stainless steel 304
  • Parameters

Technical Specification

Equipment category: fixed type

Outer box size: 1270 * 1000 * 2020 (L * W * H)

Cleaning compartment size: 693 * 828 * 935 (L *W * H)

Total volume: 536L

Power supply: 380V, 50Hz

Power: 40kVA

Environmental temperature: 5 ℃~40 ℃

Relative humidity: ≤ 80%

Atmospheric pressure range: 70kPa~106kPa

Water supply pressure: 0.2MPa~0.5MPa

Inlet water temperature: 5 ℃~40 ℃

Work cabin material: stainless steel 304

Load frame trolley material: stainless steel 304

 

Purpose: Mainly used for cleaning, disinfecting, and drying surgical instruments, glassware, anesthesia instruments, and plastic products

 

Main body insulation: ≥ 5mm insulation cotton, with low thermal conductivity, good fire resistance, strong aging resistance, and no Toxic, environmentally friendly, high-end appearance, soft texture, etc

 

Automatic control system: using human-machine interface and Siemens PLC, precise control, safe and reliable, One-click start to end, the entire process is automatically completed, displaying temperature and cleaning time, and the system can be maintained upgrade.

 

Printer: A micro printer is used to print the data of the whole cleaning process, which can be saved for a long time. It can print the mode name, cleaning date, heat drift A0 value data, cleaning time and end status of each stage

 

Operation mode (program): flexible control equipment, wide range of application, 6 cleaning modes, 3 key steps, 11 custom procedures

 

High pressure fan: using vortex high pressure fan, with high air volume, high wind speed and strong wind pressure, and continuously flow air into the cleaning tank

 

Air inlet filter: Use high-efficiency filter to prevent dry load air from being affected by microorganisms

 

Water spray system: each layer has a rotating spray arm, the spray arm has an optimized arrangement of spray holes, the design Angle, degree and quantity can be well with the spray arm rapid rotation, so that the cleaning effect to achieve the best, the circulating pump inlet is equipped with a filter screen, to prevent the spray arm blockage

 

Seal door: using tempered insulating glass sealed door, you can clearly observe the cleaning situation of the items in the cleaning cabin, the door structure is automatically opened up and down doors, save space. Double doors interlock and combined with two cylinders to seal the door, equipped with anti-clamp hand device and overload device, to maximize the safety of operators and equipment

 

Fault prompt: when the enzyme is insufficient, the water pressure is abnormal, the wind pressure is abnormal, the high and low temperature box water overtime, loading and the unloading door failure, it will sound beep, water heating and wind heating beyond the protection value, the machine screen display alarm information

 

Display: The loading door and unloading door are each installed with a communication rate of 19.2Kbps, 7-inch real color industrial touch screen. Through the touch screen, the loading door and unloading door can be turned on and off under certain working conditions, which is not only enough, can set and run the program, but also see the alarm record and the running time of each stage, so as to meet the visualization requirements of process control

 

High and low temperature water tank: the whole machine adopts the method of separate water supply from high and low temperature, and the control system pretreats in advance (the high temperature water tank is heated to about 40 degrees in advance, and the high temperature water tank is heated to about 80 degrees, depending on the system parameter setting). The purpose is to reduce the heating time of the cleaning and disinfection cycle, so as to shorten the running time of the whole program on the side

 

Heating system: mainly composed of heating pipe and heating fin. The heating pipe hethe pure water or distilled water in the storage tank to provide the heat source for the spray flushing; the heating fin mainly provides the heat source for the air inlet and plays the role of rapid drying instrument in the drying stage

 

Drying system: mainly composed of heat source, fan and ventilation pipeline. The powerful air flow generated by the fan is heated through the fin heating device, and fills the cleaning and disinfection chamber through the ventilation pipeline. The hot air flow forms a strong vortex air flow in the cleaning and disinfection chamber to dry the cleaned items.

 

Injection system: mainly composed of peristaltic pump, silicone hose, storage tank and liquid level floating ball. The peristaltic pump injects the cleaning agent, disinfectant and additional lubricant in the storage tank into the cleaning and disinfection chamber in stages to enhance the cleaning and disinfection effect.

 

Printing system: mainly composed of printer and communication cables. The relevant data generated during the operation of the equipment can be printed by the printer for easy archiving and access.

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).