SM-HTY300L series Ethylene Oxide Sterilizer

HTY series ethylene oxide sterilizer is a special equipment for low-temperature fumigation and sterilization of items enclosed in a sterilization room using ethylene oxide gas at a certain temperature (low temperature), pressure, humidity and a certain time of action. Ethylene oxide gas is a very active chemical disinfectant. It not only achieves broad-spectrum sterilization, but also can achieve reliable sterilization.
  • Parameters

Sterilization principle:

The ethylene oxide sterilizer produces a very specific alkylation effect through the contact between ethylene oxide and microorganisms, thereby inhibiting the normal reaction of microbial reactive groups, causing metabolic disorders and death.

 

Consumables for ethylene oxide sterilizer:

Ethylene oxide gas, ethylene oxide biological indicator, ethylene oxide indicator tape, ethylene oxide indicator inner card, ethylene oxide indicator outer card, ethylene oxide packaging bag.

 

Ethylene oxide tail gas processor:

The ethylene oxide tail gas processor decomposes the residual ethylene oxide tail gas after sterilization into non-toxic carbon dioxide and water vapor through high-temperature catalytic decomposition, which is directly discharged outdoors without the need for high-altitude emission pipelines. The decomposition efficiency is over 99.99%, greatly reducing the emission of ethylene oxide.

 

Technical specification

serial
number
name Technical parameter description
1. Model SMT-HTY300L
2. Rated power 4.5KVA
3. Internal dimensions 800*550*690mm( allowable deviation±5%)
4. External
dimensions
980*760*1420mm( allowable deviation±5%)
5. Nail box size 1000*780*1520mm( allowable deviation±5%)
6. Weight(kg) About 330KG (net weight)
7. Working
pressure
0kpa~ -75KPa
8. Working
temperature
30℃-60℃
9. Working
humidity
40%~80%
10. Sterilization time 3h‐99h
11. Removal
frequency
Set freely 9-99 times
12. ★Display screen Equipped with a 7-inch touch screen, 1024 * 600 pixels, 24 bit color, 256MB  DDR3+4GB eMMC memory. Compliant with EN61000-6-2:2005 and EN61000-6-4:2007 standards; Compliant with RoHS lightning surge  ±  1KV, group pulse+2kv electrostatic contact 4KV, air discharge 8KV.
Equipped with lightning surge protection function. Allow power loss<5ms.
13. ★ Display screen
shows content
Temperature, pressure, time, current stage, operating time and alarm information, as well as the operation status of the internal hardware of the equipment. You can intuitively feel which parts of the current device are working again. It is
convenient for equipment maintenance and allows for intuitive learning of   the entire equipment’s operation process and principles.
And provide actual screen interface photos.
14. ★ Number of
doors and switch
mode
Adopting a single door double-layer protective fan-shaped door opening and closing method, the internal sealing door is made of thickened explosion-proof tempered glass with a thickness of ≥ 12mm. It has high flatness, manual locking, and the door ring sealing strip can perfectly compact and seal, ensuring the sealing performance during vacuum   pumping. The external protective door adopts galvanized sheet and  high-temperature plastic powder curing process, and the upper end of the  door is equipped with an opening and closing door sensing device to increase operational safety.
15. Inner material The cavity structure is rectangular, made of 304 stainless steel with a thickness of ≥ 3mm, square structure, and processed with mirror finish. Longer service life.
16. Outer box
material
Adopting splicing technology, sheet metal baking paint, simple and easy to maintain, not prone to paint peeling and oxidation.
17. Main controller
PLC
New program design, displaying work process parameters, easy to operate, simple and easy to understand, fully realizing the accuracy, standardization, safety, and reliability of control;
18. ★ Print record
content
Printing can record sterilization time, display pressure, temperature,   humidity, sterilization process, and incorporate sterilization physical curve   printing function. Use high-capacity storage to store raw data, and print records can be saved for more than five years.
19. ★Sterilization
monitoring and
alarm
information
storage system
It has a sterilization record and alarm record traceability system, and the information can be directly displayed on the touch screen for relevant personnel to view at any time. Can store complete sterilization records of  no less than 8000 pot cycles
20. Vacuum pump Adopting an oil-free vacuum pump with extremely high vacuum degree  and corrosion resistance, the evacuation rate reaches 120L/min, and the operating sound is less than 60dB
21. Data reading Upgrade the system program, read historical data during the sterilization process, and export historical sterilization records directly from a USB
flash drive.
22. Sensor The chamber sensor is equipped with temperature, humidity, and  pressure  sensors, which automatically detect the corresponding temperature, humidity, and pressure values in the sterilization room. The   resolution of the temperature probe is 0.1 ℃, the resolution of the pressure sensor is 0.1Kpa, and the resolution of the humidity sensor is 0.1%
23. Heating method Adopting a five sided water jacket circulation heating system to ensure temperature uniformity within the sterilization chamber
24. Sterilizer and
dosing method
Built-in gas source: The sterilizing agent is a single-use, 100% pure ethylene oxide aerosol canister. The dosing method uses an internal, automatic puncture technology within the sterilization chamber, ensuring high safety, convenience, and stability.
External gas source: Uses the dedicated connecting pipe provided with the equipment, connecting one end to the machine and the
other end to the gas cylinder. Simply unscrew the knob when adding sterilizing agent.
Note: Both machine models are available for purchase.
25. ★ Mandatory
disability
removal system
If the traditional Chinese medicine tank has been punctured during operation and the equipment malfunctions, the system will automatically
monitor and perform forced residual discharge until all the ethylene oxide  gas inside the chamber is completely discharged. Greatly improved the safety of the device’s use.
26. Fault diagnosis Equipped with automatic fault detection, fault code content display alarm, fault sound alarm, and fault printing system. The device has a power-off memory function.
27. ★ Password
protection
Adopt password protection to prevent non operators from using it incorrectly. Some main process alarms require entering a password to clear the alarm information. After sterilization, opening the door also requires  entering a password to operate.
28. Consumable
equipment
The sterilization agent, chemical indicator outer card, chemical indicator inner card, packaging bag, chemical indicator tape, biological indicator, etc. are uniformly guaranteed and supplied by the manufacturer.
29. ★Traceability
System
Support integration with hospital traceability systems and support    multiple traceability protocols;
30. Leakage testing Equipped with an independent leak testing program, it can perform leak    testing independently outside of device operation to detect devices.
31. Biological testing
after sterilization
Temperature 37℃±2℃ Bacillus subtilis as a biological detection strain
32. Scope of
application
Suitable for sterilizing items that are resistant to heat, moisture, negative pressure, and ethylene oxide gas. For example: medical devices, endoscopes, rubber and plastic products, pharmaceuticals, textiles and biological products, cultural relics archives, instruments and meters, hygiene products, etc
33. Power supply 220V/50HZ

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).