VSM-1700B Infusion Pump

Infusion Pump is with the classic vertical design. The software compensation error is within±5% after calibration.
Double CPU and numeric keypad make it safe and more user friendly.
Adjustable Levels Setting: 10 levels setting for occlusion, air bubble and alarm volume
Strong Battery Backup: 3000mAh battery and backup time more than 10hrs.
User Friendly: Big Screen and numeric keypad
Dual Occlusion Sensor: Up and down occlusion sensor with DPS system
Infusion Mode: Volume Mode, Drip Mode, Time Mode, Drug Mode
  • Parameters

Technical Specification

 

Infusion Mode Volume Mode, Drip Mode, Time Mode, Drug Mode
Rate Unit ml/h, volume/time, d/min
IV Sets Standard single use IV sets ( 10,15,20,60d/mL, with diameter 3.4 ~ 4.5mm)
Flow Rate 1.0ml/h~1200ml/h

1.0d/min~400d/min

Increment 1.0-99.9ml/h in 0.1ml/h step;100-1200ml/ in 1ml/h step

1-400d/min in 1d/min step;

Deviation Flow Rate:≤5%(after calibration)
VTBI 0.1~9999.9 ml
Total Volume 0.0~9999.9 ml
Time 1min~99h00min
Purge Rate 600ml/h,display purge volume
KVO 1.0ml/h~5.0ml/h,adjustable
Keypad Numeric keypad,
BOLUS Bolus function available, flow rate adjustable
Night Mode Screen to be dim automatically in 5mins after standby time expired.
Occlusion pressure detector Upstream and downstream pressure detection,  40KPa~130KPa, 10 levels adjustable with dynamic pressure value display
Air Bubble Detector Ultrasonic detection, ≥50ul,Single bubble volume: 50~300 μl, 10 levels adjustable.
Volume 10 levels adjustable
Motor Anti-reverse Function Anti-reverse function to prevent upstream
IV Set Management Open system, accept different IV brands after calibration
Self-Testing Self-Testing before startup and during infusion
Audio Visual Alarm Message Air bubble, upstream occlusion, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery empty, battery disengaged, AC Power disengaged, motor error, pump error, pressure sensor error, parameter error, drip sensor error, drip sensor disengaged, bottle empty, system error
Screen 3.2inch brightness LCD
Power Supply AC Power:100V~240V,50Hz/60Hz,≤25VA
Battery Rechargeable Lithium battery, DC11.1V,3000mAh;operating time: ≥10h @25ml/h, displaying remaining battery
Operation Condition Temperature:+5℃~+40℃, Humidity:20%~90%,Air pressure:70~106KPa
Transport & Storage Temperature :-20℃~+55℃,Humidity:10%~95%,Air pressure:50~106KPa
Classification Type CF, Class I, IPX3
Dimension 145mm×150mm×200mm;Weight:1.7kg

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp
    Email