VSM-IP3 Infusion Pump

KVO Status: Auto progress KVO mode. Keep the patients veins open
Pressure Monitoring: Over voltage protection. The blocking pressure can be detected precisely and sensitively by Pressure sensor installed in the push handle
Data Storage: Data storage function, convenient for medical staff to review historical alarm information
Audible Alarm: Sensitive alarm reminder ti ensure injection safety in real time
One-Key Operation: Fulfill conversion between d/min and ml/h
Safe And Reliable: System self-test is completed as turning on, which ensures safe work; Real-time bubble monitoring, more secure and reliable
  • Parameters

Technical Specification

Show • 3 inch monochrome LCD display
Infusion Speed • 1ml/h – 1200ml/h can be incremented or decreased by 0.1ml/h
Infusion Volume Accuracy Error • ±5% (ordinary infusion set)
Infusion Volume Preset • 0.1ml – 9999.9ml can be decreased in increments of 0.1ml
Blocking Pressure • High: 110kpa   Medium: 80kpa   Bottom: 40kpa”
KVO • 1ml/h – 5ml/h can be decreased in increments of 1ml/h
Voltage • Power supply voltage AC 100~240VAC,
• power frequency: 50/60Hz battery input 9.5V-12.6V
Power Consumption • Not more than 35VA
Built-In Battery Working Time • d.c11.1V not less than 2000mA,not less than 12 hours
Dimensions and Weight • 90*205*151mm     • ≈1.5kg
Safety Classification • Class I, type BF general equipment with internal power supply
Waterproof Level • IPX1
Working Environment • Ambient temperature: 10~30℃
• Relative humidity: 30%~75%• Atmospheric pressure: 860hPa–1060hPa• The infusion pump should work in an environment where there is no strong shock and vibration, water and other fluids cannot invade the inside of the device, and there is no corrosive gas around
Storage Environment • The packaged infusion pump should not exceed 93%

(no condensation), and no corrosive gas will pass through a good room, and the indoor temperature conditions are: -20℃~+55℃

 

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp
    Email