DEF-5000X Defibrillator Monitor

8 inch High resolution & full color
Sweep speed: 25mm/sec
Information: Heart Rate.Lead/Pads. Alarm. On/Off. SpO2. AED
Functions and prompts Alarm selection and delivered energy limits.
6 languages to choose from
  • Features

  • Parameters

  • 1. Display
    Screen type: High resolution & full color
    Screen size: 8 inch
    Sweep speed: 25mm/sec
    Information: Heart Rate.Lead/Pads. Alarm. On/Off. SpO2. AED
    Functions and prompts Alarm selection and delivered energy limits.
    6 languages to choose from
    2. Defibrillator
    Waveform: Biphasic (BTE)
    Recharge Time: Less than 7 seconds with a new, fully charged battery.
    Energy display: Monitor display shows both selected and delivered energy.
    Type of charging prompts: Voice and visual prompts.
    Electrode impedance measurement range: 0-250 ohms.
    3. ECG Monitoring
    Patient connection: 3-lead ECG cable or 5-lead ECG cable paddles.
    Lead selection: Display on monitor paddles I II III AVR AVL AVF V.
    ECG size: 0.250.511.524 cm/mV displayed on the monitor.
    Heart rate: 20-300 BPM.
    Heart rate alarm: display on monitor on/off, user selectable.
    Smart alarms: beep/voice announcements indicate shockable rhythms.
    4. Battery
    Type: rechargeable Ni MH battery 12V.
    Operating time: for a new, fully charged battery:
    60 defibrillator discharges at maximum energy or at least 3 hours of continuous ECG monitoring.
    Other parameters affect operating time for various functions.
    5. SpO2 Module (Options)
    Measurement range: 30~100%±2% between 80%~90%other±5%
    Alarm range: user defined upper and lower limit.
    Alarm accuracy: ±10%within the set values.
    Alarm time accuracy: less than 12 sec. Pulse Oximeter
    6. Recorder
    Paper: 50mm thermal.
    Speed: 12.5mm/sec.25mm/sec.50mm/sec. User selectable delay of 6 seconds.
    Printing method: High resolution thermal print head.
    Print Modes: Manual or automatic, user configurable. On/off control: front panel and paddle.
    Automatic function: 9-second recording triggered by alarm activation, defibrillator charge or defibrillator discharge.
    7. EtCO2 Module (Options)
    CO2 range 0 to 13%(0-98.8mmHg@BTPS)
    CO2 accuracy<5.0%CO2(for BTPS)±3 mmHg
    >5.0%CO2(at BTPS)<10%of reading
    Respiratory rate 3~60 BPM Measurement accuracy±1BPM
    8. Manual Mode
    Energy selection: Selectable at 2571020305070100150200300360 joules.
    Synchronized mode: Synchronizes the defibrillator pulse with the R-wave.
    The message "SYNC" is displayed on the monitor.
    9. NIBP(Options)
    Method: automatic oscillation
    Working mode: manual/automatic
    Measure: adult: 10-250mmHg
    Ement: pediatric: 10-200mmHg
    Ement: neonatal: 10-135mmHg
    10. AED Mode
    AED function:automatic analysis and charging x3 with programmable automatic energy level selection, on-screen prompts and voice prompts.
    Shock capable rhythms: Ventricular fibrillation with amplitude>=200uV Ventricular tachycardia with rates>=140bpm and QRS complex
    wave duration>=140ms.
    Charge control: front panel, push button on paddle.
    Prompts: Voice and visual prompts.
    11. Pacemaker (Options)
    Type: VVI
    Pulse type:rectangular,constant current
    Pulse amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater).
    Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
    Multifunctional Electrode: (MFE)Pads: multipurpose defibrillation/pacing electrodes
    Pause: pacing pulse rate is reduced by a factor of 4 upon activation
    Refractory period: NC(VVI requirements do not have this specification)
    Pulse width: (20+1.5 ms)
    Output protection: Fully defibrillator protected and isolated

Technical Specification

 

Specification of the physical electronic isolation defibrillator

Electromagnetic compatibility of the battery and rhythm detection

Performance are described in this section

 

Data Acquisition and Analysis

The Defibrillator is no longer automatically set to a specific frequency response.

There are two diagnostic frequency options: 0.05-150 Hz diagnostic frequency filter and 0.05-40 Hz filtered diagnostic frequency filter.

See chapter 7 for switching between these two options.

 

Waveform Details

The following tables show the waveforms provided by the defibrillator when connected to resistive loads of 25,50, and 100 ohms and set to its maximum output.

The waveforms are identified by the defibrillator peak current values (Ip) for two-phase operation:

Duration of the first output phase (tphase1) and duration of the second output phase (tphase2).

The indicated values are within 10%.

Waveform: Truncated exponential curve Biphasic

 

Output Energy Accuracy

+/-10% or 1J (whichever is greater) at 50 ohms

+/-15% or 1J (whichever is greater) at 25 to 100 ohms

 

Charge Time

<06 seconds @200 J (with a Ni-MH 12 volt battery).

<12 seconds @360J (with a Ni-MH 12 volt battery after 15 discharges).

<15 seconds @360J(without battery 90%AC mains voltage)

Indication of the state of charge:acoustic and graphic.

 

Output

Adult paddle, pediatric adapter, and multipurpose hands-free adapter available.

Synchronizer: delivers power within 60 msec.

Disarm: Front panel switch.

 

Energy Select

External:2 5 7 10 20 30 50 70 100 150 200 300 360 J.

 

Heart Rate SpO₂Alarm

Auditory: 5-pulse 800 tone with a PW of 150 msec, a PRI of 225 msec,and a repetition interval of 10 seconds.

Visual: The heart rate alarm flashes the displayed heart rate at 2 Hz.

This indicator is located at the top of the display and is 0.4″high and 0.28 to 0.840″wide,depending on the number of digits in the heart rate.

It is amber, black, white, or the color of the display text.

 

Lead Fault Alarm

Audible: trio tone with 3 pulses, 500 Hz,with a PW of 200 msec and a PRI of 310 msec.

When the HR alarm is triggered or the pacemaker is on, the lead error tone is repeated at a 20-second repetition interval.

Visual: When a lead error occurs, the message “LEAD FAULT” is displayed along with a dashed line across the width of the trace.

The text is 0.18″ high and is the color of the display text.

The dashed line is 5″ long and corresponds to the width of the display. The signal is not modulated.

 

Physiological Alarms(SpO₂)(Options)

Acoustic: See heart rate alarm

Visual: Physiological alarms make the displayed parameter flash at 2 Hz.

The color is amber,white,or the same as the colored text on the display.

Mute Duration: 90 seconds.

 

Heart Rate SpO₂Alarm

Auditory: 5-pulse 800 tone with a PW of 150 msec, a PRI of 225 msec, and a repetition interval of 10 seconds.

Visual: The heart rate alarm flashes the displayed heart rate at 2 Hz.

This indicator is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide, depending on the number of digits in the heart rate. It is amber,black,white,or the color of the display text.

 

NIBP (Options)

Method:               automatic  oscillation

Working mode:         manual/automatic

Measure:adult:          10-250mmHg

Ement:pediatric:        10-200mmHg

Ement:neonatal:        10-135mmHg

 

End-tidal CO2(EtCO2)

Safety type ETCO2: BF

Power consumption 12.0V±0.2V DC

Power consumption 100mA(typical with pump on), 200mA(extreme conditions)

Operating temperature range 5~50℃

Shipping/storage temperature range -20~+70℃

Relative humidity 0-85%(non-condensing)

Dimensions 96×91×36mm

CO2 range 0 to 13%(0-98.8mmHg@BTPS)

CO2 accuracy<5.0%CO2(at BTPS)±3 mmHg

>5.0%CO2(at BTPS)<10% of reading

Respiratory rate 3~60 BPM

Measurement accuracy ±1 BPM

Warm-up time 10 seconds

Detector response time: 10mS,

System: depends on implementation, pneumatics and water separation technology Flow control 50~250ml/min

Interface Highly configurable serial digital interface (TTL/RS232)

Automatic offset calibration based on time, temperature and as needed

 

Pacemaker(Options)

Type: VVI

Pulse type: rectangular, constant current

Pulse amplitude: 0 to 180 mA±10% or 5 mA(whichever is greater).

Pacing frequency: Variable from 30 ppm to 180 ppm ± 1.5%(increments or decrements by a value of 2 ppm)

Multi-Function Electrode: (MFE)Pads: Multi-purpose defibrillation/pacing electrodes

Pause: pacing pulse rate is reduced by a factor of 4 upon activation

Refractory period: NC(VVI requirements do not have this specification)

Pulse width:(20+1.5 ms)

Output protection: Fully defibrillator protected and isolated

 

Operating

Temperature*: 0 to 45°C

Humidity*(NC): 15 to 95%RH(30 to 90% with CO2 probe)

Vibration*: MIL-STD 810E

Shock/Fall*: MIL-STD 810E

Altitude: Up to 4572 M(15000 feet)

Transportation and Storage:

Temperature:-30 to 70℃(-20 to 70℃ with CO2 probe)

Humidity:15 to 95% RH(non-condensing)

Atmospheric pressure: 860 to 1060 hPa

Shock/Vibration:ISTA 1A

Enclosure protection*: Solid Foreign matter:IEC 529 IP2X

Water: IEC 529 IPX4.

All tests were performed in accordance with the defibrillation standard AAMI DF-2

 

Frequency Response

Automatically adjusted to the frequency response of the monitor.

 

Battery

High capacity type: Ni-MH 12V volt

Up to 4 hours ECG monitoring or 110 full energy

charges or 3 hours combined ECG SpO₂and monitoring Proper battery maintenance is required to maintain maximum available capacity.

Low battery indicator:

Flashing low battery icon on display and flashing LED on front panel.

Recharge speed: 80% in 7.5 hours. 100% in 9 hours.

 

General

Weight: 4.95 kg(basic equipment).

Size: 13×12.5×5.3 inches (33×31.8×13.5 cm).

 

Operating Power

Ni-MH 12 volt

SAED Rhythm detection performance

The algorithm defibrillator SAED exceeds the requirements of ANSI /AAMI.

 

Recorder

Type: high resolution thermal array.

Annotation: time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.

Paper width: 50 mm.

Paper speed: 25 mm/sec 50 mm/sec 12 leads 50 mm/sec

Delay: 6 sec.

Related Products

SMT-050DH Double column Digital Radiography System (Hand-driven)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

VSM-3200T 32kW 400mA Veterinary Digital Radiography System

1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life. 2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality. 3. Intelligence high voltage control system with various APR. 4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose. 5. High standard digital image processing system provides more post-processing and meets clinical needs.

SM-800L 2-8°C Medicine Refrigerator

Meet the requirements of the new version GSP for medicine storage. Can be used for medicine, reagents and various items that need cold storage. Suitable for hospitals, clinics, blood stations of health and epidemic prevention systems, university laboratories, etc.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).