SMT-350B Ligature Vessel Sealing System

The 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar, auto bipolar seven working modes.
  • Parameters

Features

The output of this machine is fully suspended, with two independent and isolated CF type anti-defibrillation application parts (Monopolar and Bipolar), Non-AP、Non-APG type common equipment, and 220V ± 10% or 110V ± 10% network power supply.

 

Specification

The 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar, auto bipolar seven working modes.

Full-function automatic power compensation.

The high-frequency generator has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope, laparoscope and other endoscopes.

Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.

Patient circuit bipolar electrode plate contact quality detection system.

Monopolar output can be controlled either by hand or foot, and monopolar/bipolar automatic output.

* This machine has a power-off protection circuit, which can memorize the output set value of each function in real time.

Remote fault diagnosis.

* Human voice alarm function

Passed EMC test.

Rated output power:

Pure cut:1W~350W (Max. 400W, load 500 Ω);
A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis. (No-focus precision cutting, 100% cutting.)

Blend cut 1:1W~250W (load 500 Ω);
Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode. (Superficial focal gamma accurate cutting 80% cutting, 20% coagulation.)

Blend cut 2: 1W~200W (load 500 Ω);
The mode is used for vaporization of prostatic tissue or any fat tissue. The higher output wattage gives fast cutting effect of the tissue. (60% cutting, 40% coagulation.)

ENDU Cut: 99% (load 500 Ω);
The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode.

Spray coagulation:1W~80W (load 500 Ω);
Spray output is made for direct coagulation at the tissue with spark. Above spark does not give any cutting effect as its CREST FACTOR is high. (Massive coagulation)

Desicate coagulation:1W~120W (load 500 Ω);
Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries it ensures pinpoint desiccation with less destruction of peripheral tissue.

BI-COAG & BI-CUT:1W~100W (load 100 Ω);
BI-COAG (Standard Bipolar)
For highly precise control over coagulation process and privations of carbonization.

BI-CUT (Automatic Bipolar)

This bipolar cut technology nearly eliminate excessive current even during precision cutting in minute tissue structure

Power consumption of the whole machine: ≤ 1100VA. (cut function 350W);

 

Normal operation

Ambient temperature range: 5 ℃~40 ℃;

Relative humidity range: ≤ 80%;

Atmospheric pressure range: 86.0~106.0kPa;

Power supply: 220V±10%, 50±1Hz; or 110V±10%, 60±1Hz

Working frequency: 416kHz;

 

Transportation and storage

Ambient temperature range: – 40 ℃~55 ℃;

Relative humidity range: ≤ 95%;

Atmospheric pressure range: 50.0~106.0kPa.

 

Configuration List

Main unit 1 PC□
Disposable hand switch 2PCS□
Disposable neutral plate 3PCS□
Disposable neutral plate cable 1 PC□
Closing and cutting electrode forceps 1 PC□
Bipolar forceps cable 1 PC□
Bipolar foot switch 1 PC□
Monopolar foot switch 1 PC□
Power cable 1 PC□
GBXP5*20(5A) Fuse 2PCS□
PACKING LIST 1 PC□
USER’S MANUAL 1 PC□
WARRANTY CARD 1 PC□
QUALITY CARD 1 PC□
Related Products

SMT-050DE Double Column Digital Radiography System (Electric)

Double column Digital Radiography System adopts large span independent ball tube frame design, easy installation, small occupation area, convenient maintenance. Four-way floating bed surface, easy to use and positioning. The lifting and lifting of X-ray source and bidirectional follow-up of horizontal position of bed column can reduce the positioning time and meet the requirements of large-flow clinical examination. Applicable to orthopedics, emergency room, operating room, etc.,As human head, limbs, chest, spine, lumbar spine for medical diagnosis

AED-5 Automated External Defibrillator

1. 2 languages to choose from (by end user) 2. Bluetooth for data transmission (standard) 3. Daily, weekly and monthly self test 4. Use of AED in pocket (does not need to be opened) 5. Extra pocket in the bag for first aid products 6. IPX55 water and dust resistant 7. 5 volume levels (by the end user) 8. Button for adult/child mode

SMT-40E Medical Ventilator

No external gas source can be independently long-term work (Bring your own air) The operator control panel is with clear LCD display. Easy to operate. Whole body is compact, easy to install on a ventilator tower crane, ambulance. Friendly interface, easy operation and intuitive. Offers three power: AC, Car Power, Built-in battery Self-powered support ventilator work more than two hours.

SMH-60B 5-part Auto Hematology Analyzer

1. Throughput 60T/H.       2. 14-inch touch screen. 3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting. 4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC. 5. Large storage capacity: 300,000 results(including histogram, scattergram, patient information).

Leave A Message


    Products
    Contact
    WhatsApp